  1. .ds FF Flex\s-1FAX\s+1
  2. .nr H1 0
  3. .H 1 "Introduction"
  4. .P
  5. This document describes the features of the 2.2.2 release of
  6. the \*(FF facsimile system;
  7. \*(FF supports:
  8. .BL
  9. .LI
  10. sending facsimile
  11. .LI
  12. receiving facsimile
  13. .LI
  14. polled retrieval of facsimile
  15. .LI
  16. transparent shared data use of the modem
  17. .LE
  18. .P
  19. Outgoing documents can be any format; the \f2sendfax\fP(1) program uses a
  20. rule-based definition file similar to the System V \f3/etc/magic\fP file 
  21. to deduce document types and to decide how to convert each document
  22. to a form suitable for transmission (either PostScript\(tm or \s-1TIFF/F\s+1).
  23. Automatic cover page generation is supported and users can easily
  24. tailor cover pages to their environment.  A simple text-based
  25. phonebook database is supported by sendfax.  Information is also
  26. provided on how to trivially setup an email to fax gateway service.
  27. .P
  28. Incoming facsimile are stored in a receiving area as \s-1TIFF/F\s+1 files and
  29. may be automatically delivered by mail and/or printed.  A fax server
  30. status program, \f2faxstat\fP(1), can be used to monitor the send and receive
  31. queues, as well as the state of facsimile servers.
  32. .P
  33. Fax modems may be shared with outgoing data communication applications
  34. that honor the ``\s-1UUCP\s+1 locking protocol.''  These applications typically
  35. include: cu, tip, kermit, uucp, slip, and ppp.  The system can also be
  36. configured so that incoming data calls cause the system to invoke the
  37. standard system getty program.
  38. .P
  39. The software is structured around a client-server architecture.  One
  40. facsimile server process exists for each fax modem on a network.
  41. Clients may send facsimile from any machine that can communicate with
  42. the machine(s) on which the server(s) reside.  Client software is
  43. designed to be lightweight and easy to port; imaging can be offloaded
  44. to the server or done on the client.  (Imaging is, however, typically
  45. done on the server because it simplifies administration.)  Multiple
  46. modems may be located on a single machine.  An access control mechanism
  47. is included to control which users on which machines may submit
  48. documents for transmission.
  49. .P
  50. The system supports a wide variety of fax modems.  Any Class 1,
  51. Class 2, or Class 2.0 modem should work with the software.
  52. The following table lists
  53. the modems that have been used successfully with the software.
  54. Note however that some modems perform better than others.  
  55. Wherever possible the FlexFAX
  56. software works around known modem problems or restricts modem usage in
  57. order to provide a functioning system. 
  58. Beware however that several
  59. Class 2 modems do not correctly implement the \s-1+FDIS\s+1
  60. command as specified in SP-2388-A. 
  61. As a result they are not recommended for use
  62. with this software because their firmware limitations make it possible
  63. to send only low-resolution, 1D-encoded, facsimile data.
  64. Chapter 7 of this document includes information about many
  65. modems that have been tried.
  66. .KS
  67. .TS
  68. l l l l.
  69. Manufacturer    Model    Notes    Firmware Rev
  70. _
  71. Abaton    InterFax 24/96        unavailable
  72. AT&T Paradyne    DataPort 14.4    1,2,+    >= C01.22.00
  73. Boca Research    \s-1M1440E\s+1    2    >= V1.270
  74. Boca Research    \s-1M1440E/RC32ACL\s+1    2,@    V1.000
  75. CPI    ViVa 14.4/FAX    2    V1.10 172-502402-013
  76. Dallas Fax    <something>    2    not recommended
  77. Digicom    Scout+    1,+    >= 2A19/2931
  78. Dynalink (?)    Dynalink 1414VE    2    CBS-03
  79. Everex    EverFax 24/96D    2    >= 901231
  80. Hayes    Optima 144    1    unknown
  81. Hayes    Optima 2400+Fax96    2    >= TR00-J260-001 XXX
  82. Intel    SatisFAXtion 400e    1    >= U20-28F001BX-5.00
  83. Logicode    Quicktel Xeba 14.4    2    V0.500 TR14-Jxxx-001
  84. Multi-Tech    \s-1MT1432BA\s+1, \s-1MT224BA\s+1    2,*,+    >= 0307 I
  85. Multi-Tech    \s-1MT1432BG\s+1    2    0109A
  86. Nuvo    Voyager \s-196424PFX\s+1    1    AF-C2500-E0
  87. \s-1PPI\s+1    \s-1PM14400FX\s+1    2,\(dd    >= 2.17
  88. Supra    SupraFAX v.32bis    1,2    >= V1.200-C
  89. Supra    SupraFAX v.32bis/\s-1RC32ACL\s+1    2,@    >= V1.000
  90. Telebit    T3000, WorldBlazer, QBlazer    2    >= LA7.01
  91. Twincom    144/DF    2    >= V1.200
  92. USRobotics    Courier    1,2.0    Sup4.1/DSP11
  93. USRobotics    Sportster    1    Sup4.1/DSP10
  94. Zoom    VFX    1,2    V2.00
  95. Zero One Net.    ZyXEL U1496    2,\(dg    >= 5.01
  96. .TE
  97. .sp
  98. .fi
  99. Notes:
  100. .in +\w'@ 'u
  101. .ta \w'@ 'u
  102. .ti -\w'@ 'u
  103. 1    The modem supports the TIA/EIA-578 "Class 1" specification.
  104. .ti -\w'@ 'u
  105. 2    Class 2 means the modem supports the
  106. TIA/EIA-592 draft SP-2388-A of August 30, 1991.
  107. .ti -\w'@ 'u
  108. 2.0    Class 2.0 means the modem supports the
  109. TIA/EIA-592 ``Class 2.0'' specification.
  110. .ti -\w'@ 'u
  111. *    There are apparently many variants of the
  112. \s-1MT1432BA\s+1, the following models are known to work:
  113. \s-1MT1432BA\s+1, \s-1MT1432BA/A\s+1, \s-1MT1432MK\s+1, \s-1MT1432PCS\s+1.
  114. .ti -\w'@ 'u
  115. @    \s-1/RC32ACL\s+1 refers to second-generation products made
  116. with the Rockwell \s-1RC32ACL\s+1 part and different firmware.
  117. .ti -\w'@ 'u
  118. +    Modem is recommended for use with this software.
  119. .ti -\w'@ 'u
  120. \(dd    \s-1PM14400FX\s+1 refers to the \s-1PM14400FXMT\s+1
  121. and \s-1PM14400FXSA\s+1 models.
  122. .ti -\w'@ 'u
  123. \(dg    U1496 refers to the U1496E, U1496E+, and U1496S models.
  124. .in -\w'@ 'u
  125. .KE
  126. .H 2 "Release Identification Information" 
  127. .P
  128. Following is the release identification information for \*(FF
  129. .P
  130. .KS
  131. .TS
  132. lfPB l .
  133. \f3Software Option Product\fP    T{
  134. .fi
  135. \*(FF Facsimile Software
  136. T}
  137. .sp 0.5
  138. \f3Version\fP    T{
  139. .fi
  140. 2.2.2
  141. T}
  142. .sp 0.5
  143. \f3System Software Requirements\fP    T{
  144. .fi
  145. IRIX 4.X or 5.X
  146. T}
  147. .TE
  148. .KE
  149. .H 2 "Copyright Notice"
  150. \(co \f3Copyright 1988, 1989, 1990, 1991, 1992, 1993, 1994 Sam Leffler\fP
  151. .br
  152. \(co \f3Copyright 1991, 1992, 1993, 1994 Silicon Graphics, Inc.\fP
  153. .fi
  154. .vs 10
  155. .na
  156. .nh
  157. Permission to use, copy, modify, distribute, and sell this software and 
  158. its documentation for any purpose is hereby granted without fee, provided
  159. that (i) the above copyright notices and this permission notice appear in
  160. all copies of the software and related documentation, and (ii) the names of
  161. Sam Leffler and Silicon Graphics may not be used in any advertising or
  162. publicity relating to the software without the specific, prior written
  163. permission of Sam Leffler and Silicon Graphics.
  164.  
  165. THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
  166. EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
  167. WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
  168.  
  169. IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
  170. ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
  171. OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
  172. WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
  173. LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
  174. OF THIS SOFTWARE.
  175. .H 2 "On-Line Release Notes"
  176. When you install the on-line documentation for a product, 
  177. you can view the release notes on your screen 
  178. as you would an on-line manual page.  
  179. .P
  180. Refer to the \f2relnotes(1)\fP and
  181. \f2grelnotes(1)\fP manual pages for how to
  182. access the on-line release notes.
  183. .H 2 "On-Line Manual Pages"
  184. The following manual pages are provided online with
  185. the client-side part of \*(FF:
  186. .TS
  187. l l.
  188. \f2flexfax\fP\|(1)    introduction to \*(FF operation and file formats
  189. \f2fax2ps\fP\|(1)    convert a \s-1TIFF\s+1 facsimile to compressed PostScript
  190. \f2faxalter\fP\|(1)    alter parameters of a facsimile job queued for transmission
  191. \f2faxcover\fP\|(1)    generate a cover page for an outgoing facsimile
  192. \f2faxmail\fP\|(1)    convert a mail message to PostScript for sending as facsimile
  193. \f2faxrm\fP\|(1)    remove a facsimile job queued for transmission
  194. \f2faxstat\fP\|(1)    display facsimile server status
  195. \f2sgi2fax\fP\|(1)    convert an SGI image file for facsimile transmission
  196. \f2sendfax\fP\|(1)    submit a facsimile job for transmission
  197. \f2textfmt\fP\|(1)    covert text to PostScript for facsimile transmission
  198. .TE
  199. .P
  200. The following manual pages are provided online with
  201. the server-side part of \*(FF:
  202. .TS
  203. l l.
  204. \f2intro\fP\|(4F)    introduction to \*(FF operation and file formats
  205. \f2dialtest\fP\|(1M)    \*(FF dial string processing rules test program
  206. \f2faxaddmodem\fP\|(1M)    configure a facsimile modem for use with \*(FF
  207. \f2faxanswer\fP\|(1M)    tell facsimile server to answer the telephone
  208. \f2faxcron\fP\|(1M)    \*(FF routine maintenance script
  209. \f2faxd\fP\|(1M)    facsimile modem server
  210. \f2faxd.recv\fP\|(1M)    facsimile job submission server
  211. \f2faxquit\fP\|(1M)    tell facsimile server to terminate
  212. \f2faxrcvd\fP\|(1M)    \*(FF notification script for received facsimile
  213. \f2notify\fP\|(1M)    \*(FF user notification script
  214. \f2pollrcvd\fP\|(1M)    \*(FF script for delivering facsimile received by polling
  215. \f2ps2fax\fP\|(1M)    image PostScript for facsimile transmission
  216. \f2recvstats\fP\|(1M)    summarize \*(FF transmission accounting statistics
  217. \f2transcript\fP\|(1M)    print a transcript of the last call placed by a \*(FF server
  218. \f2xferstats\fP\|(1M)    summarize \*(FF transmission accounting statistics
  219.  
  220. \f2cinfo\fP\|(4F)    remote facsimile machine control parameters database
  221. \f2config\fP\|(4F)    \*(FF per-modem server configuration database
  222. \f2dialrules\fP\|(4F)    \*(FF dial string processing rules
  223. \f2hosts\fP\|(4F)    host name data base
  224. \f2info\fP\|(4F)    remote facsimile machine capability database
  225. \f2log\fP\|(4F)    \*(FF session log files
  226. \f2pagesizes\fP\|(4F)    \*(FF page size definitions
  227. \f2recvq\fP\|(4F)    received facsimile document format
  228. \f2sendq\fP\|(4F)    \*(FF facsimile transmission job description
  229. \f2status\fP\|(4F)    server status database
  230. \f2tsi\fP\|(4F)    Transmission Subscriber Identification (\s-1TSI\s+1) database
  231. \f2typerules\fP\|(4F)    \*(FF file type identification and conversion rules
  232. \f2xferlog\fP\|(4F)    \*(FF facsimile transfer log
  233. .TE
  234. .P
  235. To access an online manual page, select "Man Page" from the Help menu
  236. of the Toolchest (under IRIX 5.2); or use the \f2man\fP(1) command.
  237. .H 2 "Product Support"
  238. This is free software and is not supported by Silicon Graphics.
  239. However, there is a very active mailing list for users of this software
  240. located on the host sgi.com.
  241. If you want to join this mailing list or have a list-related request
  242. such as getting your name removed from it, send a request to
  243. .sp .5
  244. .ti .5i
  245. \f3majordomo@whizzer.wpd.sgi.com\fP
  246. .sp .5
  247. For example, to subscribe, send the line "subscribe flexfax" in
  248. the body of your message.  The line "help" will return a list of
  249. the commands understood by the mailing list management software.
  250. .P
  251. Submissions (including bug reports) should be directed to:
  252. .sp .5
  253. .ti .5i
  254. \f3flexfax@sgi.com\fP
  255. .sp .5
  256. Note that the mailing list has many people on it.  Please take this
  257. into consideration when posting notes to it; i.e. avoid posting large
  258. trace logs and the such.  Also, when corresponding about this software
  259. please always specify:
  260. .DL
  261. .LI
  262. what version you have (use ``versions flexfax.sw''),
  263. .LI
  264. what system you are running on, and,
  265. .LI
  266. if the problem is modem-related, identify it and the firmware revision.
  267. .LE
  268. .P
  269. For example: ``FlexFAX release 2.2.2 under IRIX 5.2;
  270. ZyXEL 1496E with 6.11a firmware.''
  271. .P
  272. If you find that the flexfax mailing list has too much traffic for you,
  273. there is also an announcements-only mailing list called \f3flexfax-announce\fP.
  274. This can be subscribed in the same way that you subscribe to the
  275. flexfax mailing list: send "subscribe flexfax-announce" to the
  276. Majordomo list handler on \f3whizzer.wpd.sgi.com\fP. 
  277. Note that there is no
  278. need to subscribe to both mailing lists; postings to the announcement
  279. list are automatically fed to the normal flexfax list.
  280. .H 2 "Document Overview"
  281. This document contains the following chapters:
  282. .AL 1 +5
  283. .LI
  284. Introduction
  285. .LI
  286. Installation Information
  287. .LI
  288. Troubleshooting
  289. .LI
  290. Changes and Additions
  291. .LI
  292. Bug Fixes
  293. .LI
  294. Known Problems and Workarounds
  295. .LI
  296. Modem Information
  297. .LI
  298. Contributed Software
  299. .LE
  300. .P
  301. First time installers of this software should read Chapter 2
  302. carefully.
  303. The "Modem Information" chapter
  304. discusses modem-related issues and may be of